Particulate coverage from base of the neck and around entire head except for Sure‑Fit™ panel at crown. All critical areas of particulate penetration as identified by NFPA have particulate barrier. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition. EN13911: 2017.
Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 96% particulate efficiency for particulates between 0.1 and 1.0 microns. PGI quilted BarriAire composite fabrics recently achieved Viral Filtration Efficiency (VFE) Rating of 96.8% and Bacterial Filtration Efficiency (BFE) Rating of 97.9% (as conducted by Nelson Labs, U.S.A.). NFPA 70E Hazard Risk Category 4.
NOTE:- All hoods and masks are manufactured to the required EN standards, and the PGI hoods have also been: "Independently Tested & Certified", with a fitted RFID tag. This additional testing is a requirement as the hood s have been changed from the original tested design.
T: 01924 408598